Blob Blame History Raw
From 79b68f1b48b0967da999945e310aef628c9bca4c Mon Sep 17 00:00:00 2001
From: Przemyslaw Czarnowski <przemyslaw.hawrylewicz.czarnowski@intel.com>
Date: Thu, 18 Apr 2013 10:51:37 +0200
Subject: [PATCH] imsm: monitor: do not finish migration if there are no failed
 disks

Transition from "degraded" to "recovery" made in OROM is slightly different
than the same transision in mdadm. Missing disk is not removed from list of
raid devices, but just from map. Therefore mdadm should not end migration
basing on existence of list of missing disks but should rely on count of
failed disks.

Signed-off-by: Przemyslaw Czarnowski <przemyslaw.hawrylewicz.czarnowski@intel.com>
Tested-by: Pawel Baldysiak <pawel.baldysiak@intel.com>
Signed-off-by: NeilBrown <neilb@suse.de>
---
 super-intel.c | 9 ++++++++-
 1 file changed, 8 insertions(+), 1 deletion(-)

diff --git a/super-intel.c b/super-intel.c
index 24016b7..3f15b0f 100644
--- a/super-intel.c
+++ b/super-intel.c
@@ -6886,6 +6886,12 @@ static void handle_missing(struct intel_super *super, struct imsm_dev *dev)
 	if (!super->missing)
 		return;
 
+	/* When orom adds replacement for missing disk it does
+	 * not remove entry of missing disk, but just updates map with
+	 * new added disk. So it is not enough just to test if there is
+	 * any missing disk, we have to look if there are any failed disks
+	 * in map to stop migration */
+
 	dprintf("imsm: mark missing\n");
 	/* end process for initialization and rebuild only
 	 */
@@ -6896,7 +6902,8 @@ static void handle_missing(struct intel_super *super, struct imsm_dev *dev)
 		failed = imsm_count_failed(super, dev, MAP_0);
 		map_state = imsm_check_degraded(super, dev, failed, MAP_0);
 
-		end_migration(dev, super, map_state);
+		if (failed)
+			end_migration(dev, super, map_state);
 	}
 	for (dl = super->missing; dl; dl = dl->next)
 		mark_missing(dev, &dl->disk, dl->index);
-- 
1.8.1.4