#! /bin/sh
# PCP QA Test No. 089
# interpolate a monotonic increasing value
#
# Copyright (c) 1995-2002 Silicon Graphics, Inc.  All Rights Reserved.
#

seq=`basename $0`
echo "QA output created by $seq"

# get standard filters
. ./common.product
. ./common.filter

trap "rm -f $tmp.*; exit" 0 1 2 3 15

_filter()
{
    sed \
	-e '/^$/d' \
	-e '/^[^0-9]/d' \
    | $PCP_AWK_PROG '
$2 <= 0.95 || $2 >= 1.05	{ print "oops: " $0; next }
				{ print "rate close to 1" }'
}

# real QA test starts here

# get the time of the fifth sample ... we skip the first few to ensure
# things have stablized after pmlogger startup
#
first_time=`pmval -U tmparch/bar -s5 sampledso.milliseconds | tail -1 | cut -f1 -d ' '`

# there are 70 samples in tmparch/bar, 65 after skipping the first 5 and
# the logging interval is 0.1 sec ... so more than enough for the
# 485 samples x 0.01 sec needed for pmval
#
pmval -S "@$first_time" -t 0.01 -s 485 -a tmparch/bar sampledso.milliseconds 2>/dev/null | _filter