Blame SOURCES/mysql-s390-tsc.patch

80384c
Support s390/s390x in performance schema's cycle-counting functions.
80384c
Filed upstream at http://bugs.mysql.com/bug.php?id=59953
80384c
80384c
80384c
diff -up mysql-5.5.28/include/my_rdtsc.h.p11 mysql-5.5.28/include/my_rdtsc.h
80384c
--- mysql-5.5.28/include/my_rdtsc.h.p11	2012-08-29 10:50:46.000000000 +0200
80384c
+++ mysql-5.5.28/include/my_rdtsc.h	2012-12-06 14:22:13.651823354 +0100
80384c
@@ -125,6 +125,7 @@ C_MODE_END
80384c
 #define MY_TIMER_ROUTINE_MACH_ABSOLUTE_TIME      25
80384c
 #define MY_TIMER_ROUTINE_GETSYSTEMTIMEASFILETIME 26
80384c
 #define MY_TIMER_ROUTINE_ASM_SUNPRO_X86_64       27
80384c
+#define MY_TIMER_ROUTINE_ASM_S390                28
80384c
 
80384c
 #endif
80384c
 
80384c
diff -up mysql-5.5.28/mysys/my_rdtsc.c.p11 mysql-5.5.28/mysys/my_rdtsc.c
80384c
--- mysql-5.5.28/mysys/my_rdtsc.c.p11	2012-08-29 10:50:46.000000000 +0200
80384c
+++ mysql-5.5.28/mysys/my_rdtsc.c	2012-12-06 14:22:13.672823375 +0100
80384c
@@ -224,6 +224,13 @@ ulonglong my_timer_cycles(void)
80384c
     clock_gettime(CLOCK_SGI_CYCLE, &tp);
80384c
     return (ulonglong) tp.tv_sec * 1000000000 + (ulonglong) tp.tv_nsec;
80384c
   }
80384c
+#elif defined(__GNUC__) && defined(__s390__)
80384c
+  /* covers both s390 and s390x */
80384c
+  {
80384c
+    ulonglong result;
80384c
+    __asm__ __volatile__ ("stck %0" : "=Q" (result) : : "cc");
80384c
+    return result;
80384c
+  }
80384c
 #elif defined(HAVE_SYS_TIMES_H) && defined(HAVE_GETHRTIME)
80384c
   /* gethrtime may appear as either cycle or nanosecond counter */
80384c
   return (ulonglong) gethrtime();
80384c
@@ -533,6 +540,8 @@ void my_timer_init(MY_TIMER_INFO *mti)
80384c
   mti->cycles.routine= MY_TIMER_ROUTINE_ASM_GCC_SPARC32;
80384c
 #elif defined(__sgi) && defined(HAVE_CLOCK_GETTIME) && defined(CLOCK_SGI_CYCLE)
80384c
   mti->cycles.routine= MY_TIMER_ROUTINE_SGI_CYCLE;
80384c
+#elif defined(__GNUC__) && defined(__s390__)
80384c
+  mti->cycles.routine= MY_TIMER_ROUTINE_ASM_S390;
80384c
 #elif defined(HAVE_SYS_TIMES_H) && defined(HAVE_GETHRTIME)
80384c
   mti->cycles.routine= MY_TIMER_ROUTINE_GETHRTIME;
80384c
 #else