Blame SOURCES/0040-rasdaemon-add-more-dell-labels.patch

97e186
Hello,
97e186
97e186
This patch adds labels for these Dell PowerEdge Servers:
97e186
97e186
R610,R/T710, R220, R/T620, R720/xd, R730/xd, M520, M620 and M820.
97e186
97e186
The current T610 (0F5XM3) mapping is incorrect. This patch fixes it.
97e186
97e186
Reqest review and inclusion to git repo.
97e186
97e186
Acked-by: Aristeu Rozanski <aris@redhat.com>
97e186
Signed-off-by: Charles Rose <charles.rose.linux@gmail.com>
97e186
---
97e186
Changes in v2:
97e186
- Include T110 II, T20, R/T320, M420, R/T420, R/T630, FC620, FC420
97e186
- Include additional model numbers for M820 and some 2-socket systems.
97e186
- Consolidate systems with similar maps.
97e186
---
97e186
 labels/dell | 86 ++++++++++++++++++++++++++++++++++++++++++++++++++++++++-----
97e186
 1 file changed, 79 insertions(+), 7 deletions(-)
97e186
97e186
diff --git a/labels/dell b/labels/dell
97e186
index e1a09a7..d7e797b 100644
97e186
--- a/labels/dell
97e186
+++ b/labels/dell
97e186
@@ -9,12 +9,84 @@
97e186
 #
97e186
 
97e186
 Vendor: Dell Inc.
97e186
+#### 11G ####
97e186
+# 2-socket
97e186
+# PowerEdge R610
97e186
+  Model: 0K399H, 0F0XJ6
97e186
+    DIMM_A1: 0.0.0;	DIMM_A2:  0.0.1;	DIMM_A3:  0.0.2;
97e186
+    DIMM_A4: 0.1.0;	DIMM_A5:  0.1.1;	DIMM_A6:  0.1.2;
97e186
 
97e186
-  Model: 0F5XM3
97e186
-    DIMM_A1: 0.0.0;	DIMM_A2:  0.0.1;	DIMM_A3:  0.0.2;	DIMM_A4:  0.0.3;
97e186
-    DIMM_A5: 0.1.0;	DIMM_A6:  0.1.1;	DIMM_A7:  0.1.2;	DIMM_A8:  0.1.3;
97e186
-    DIMM_A9: 0.2.0;	DIMM_A10: 0.2.1;	DIMM_A11: 0.2.2;	DIMM_A12: 0.2.3;
97e186
+    DIMM_B1: 1.0.0;	DIMM_B2:  1.0.1;	DIMM_B3:  1.0.2;
97e186
+    DIMM_B4: 1.1.0;	DIMM_B5:  1.1.1;	DIMM_B6:  1.1.2;
97e186
 
97e186
-    DIMM_B1: 1.0.0;	DIMM_B2:  1.0.1;	DIMM_B3:  1.0.2;	DIMM_B4:  1.0.3;
97e186
-    DIMM_B5: 1.1.0;	DIMM_B6:  1.1.1;	DIMM_B7:  1.1.2;	DIMM_B8:  1.1.3;
97e186
-    DIMM_B9: 1.2.0;	DIMM_B10: 1.2.1;	DIMM_B11: 1.2.2;	DIMM_B12: 1.2.3;
97e186
+# PowerEdge T710	R710
97e186
+  Model: 01CTXG,	0N0H4P, 0MD99X, 0N047H, 0PV9DG
97e186
+    DIMM_A3: 0.0.0;	DIMM_A2:  0.1.0;	DIMM_A1:  0.2.0;
97e186
+    DIMM_A6: 0.0.1;	DIMM_A5:  0.1.1;	DIMM_A4:  0.2.1;
97e186
+    DIMM_A9: 0.0.2;	DIMM_A8:  0.1.2;	DIMM_A7:  0.2.2;
97e186
+
97e186
+    DIMM_B3: 1.0.0;	DIMM_B2:  1.1.0;	DIMM_B1:  1.2.0;
97e186
+    DIMM_B6: 1.0.1;	DIMM_B5:  1.1.1;	DIMM_B4:  1.2.1;
97e186
+    DIMM_B9: 1.0.2;	DIMM_B8:  1.1.2;	DIMM_B7:  1.2.2;
97e186
+
97e186
+#### 12/13G ####
97e186
+# 1-socket
97e186
+# PowerEdge R220
97e186
+  Model: 081N4V
97e186
+    DIMM_A1: 0.0.0;    DIMM_A2: 0.0.1;
97e186
+    DIMM_A3: 0.1.0;    DIMM_A4: 0.1.1;
97e186
+
97e186
+#PowerEdge T110 II, T20
97e186
+  Model: 0PC2WT, 0PM2CW, 015TH9,  0MDHN4, 0VD5HY
97e186
+    DIMM_A1:  0.0.0;    DIMM_A2:   0.1.0;
97e186
+
97e186
+    DIMM_B1:  0.0.1;    DIMM_B2:   0.1.1;
97e186
+
97e186
+#PowerEdge R320 T320
97e186
+  Model: 0YCV59, 0Y97HY, 07DKYR, 0VJ84C,  07MYHN, 04DMNN, 0W7H8C, 0K20G5, 0V719V, 0FDT3J
97e186
+    DIMM_A1:  0.0.0;    DIMM_A2:   0.1.0;       DIMM_A3:   0.2.0;
97e186
+    DIMM_A4:  0.0.1;    DIMM_A5:   0.1.1;       DIMM_A6:   0.2.1;
97e186
+
97e186
+# 2-socket
97e186
+# PowerEdge R620/T620			R720/xd					R730/xd		T630	R730		R630	T620	M620, FC620
97e186
+  Model: 0VWT90, 07NDJ2, 0F5XM3,	0PXXHP, 0X3D66, 061P35, 0H5J4J, 00W9X3,	0599V5,		0W9WXC, 0599V5, 0H21J3, 0CNCJW,  02CD1V, 0T5TFW, 0F5XM3, 0G1CNH,  05YV77, 0PDCCX, 093MW8, 0NJVT7
97e186
+    DIMM_A1:  0.0.0;	DIMM_A2:   0.1.0;	DIMM_A3:   0.2.0;	DIMM_A4:   0.3.0;
97e186
+    DIMM_A5:  0.0.1;	DIMM_A6:   0.1.1;	DIMM_A7:   0.2.1;	DIMM_A8:   0.3.1;
97e186
+    DIMM_A9:  0.0.2;	DIMM_A10:  0.1.2;	DIMM_A11:  0.2.2;	DIMM_A12:  0.3.2;
97e186
+
97e186
+    DIMM_B1:  1.0.0;	DIMM_B2:   1.1.0;	DIMM_B3:   1.2.0;	DIMM_B4:   1.3.0;
97e186
+    DIMM_B5:  1.0.1;	DIMM_B6:   1.1.1;	DIMM_B7:   1.2.1;	DIMM_B8:   1.3.1;
97e186
+    DIMM_B9:  1.0.2;	DIMM_B10:  1.1.2;	DIMM_B11:  1.2.2;	DIMM_B12:  1.3.2;
97e186
+
97e186
+# PowerEdge M520		R420								   T420
97e186
+  Model: 0NRG83, 0DW6GX,	03WPHJ, 06HTRX, 0H1Y24, 02T9N6,  0TT5P2, 0CPKXG, 03015M, 061VPC,   0PC9H0, 0K3G34, 0PC0V5, 08NVYK
97e186
+    DIMM_A1:  0.0.0;	DIMM_A2:   0.1.0;	DIMM_A3:   0.2.0;
97e186
+    DIMM_A4:  0.0.1;	DIMM_A5:   0.1.1;	DIMM_A6:   0.2.1;
97e186
+
97e186
+    DIMM_B1:  1.0.0;	DIMM_B2:   1.1.0;	DIMM_B3:   1.2.0;
97e186
+    DIMM_B4:  1.0.1;	DIMM_B5:   1.1.1;	DIMM_B6:   1.2.1;
97e186
+
97e186
+#PowerEdge FC420, M420
97e186
+  Model: 0DPJGD, 068CTP, 0MN3VC, 0417VP
97e186
+     DIMM_A1:  0.0.0;   DIMM_A2:   0.1.0;       DIMM_A3:   0.2.0;
97e186
+
97e186
+     DIMM_B1:  1.0.0;   DIMM_B2:   1.1.0;       DIMM_B3:   1.2.0;
97e186
+
97e186
+# 4-socket
97e186
+# # PowerEdge M820
97e186
+  Model: 0RN9TC, 0YWR73, 066N7P, 0PFG1N, 0JC2W3
97e186
+    DIMM_A1:  0.0.0;    DIMM_A2:   0.1.0;       DIMM_A3:   0.2.0;       DIMM_A4:   0.3.0;
97e186
+    DIMM_A5:  0.0.1;    DIMM_A6:   0.1.1;       DIMM_A7:   0.2.1;       DIMM_A8:   0.3.1;
97e186
+    DIMM_A9:  0.0.2;    DIMM_A10:  0.1.2;       DIMM_A11:  0.2.2;       DIMM_A12:  0.3.2;
97e186
+
97e186
+    DIMM_B1:  1.0.0;    DIMM_B2:   1.1.0;       DIMM_B3:   1.2.0;       DIMM_B4:   1.3.0;
97e186
+    DIMM_B5:  1.0.1;    DIMM_B6:   1.1.1;       DIMM_B7:   1.2.1;       DIMM_B8:   1.3.1;
97e186
+    DIMM_B9:  1.0.2;    DIMM_B10:  1.1.2;       DIMM_B11:  1.2.2;       DIMM_B12:  1.3.2;
97e186
+
97e186
+    DIMM_C1:  2.0.0;    DIMM_C2:   2.1.0;       DIMM_C3:   2.2.0;       DIMM_C4:   2.3.0;
97e186
+    DIMM_C5:  2.0.1;    DIMM_C6:   2.1.1;       DIMM_C7:   2.2.1;       DIMM_C8:   2.3.1;
97e186
+    DIMM_C9:  2.0.2;    DIMM_C10:  2.1.2;       DIMM_C11:  2.2.2;       DIMM_C12:  2.3.2;
97e186
+
97e186
+    DIMM_D1:  3.0.0;    DIMM_D2:   3.1.0;       DIMM_D3:   3.2.0;       DIMM_D4:   3.3.0;
97e186
+    DIMM_D5:  3.0.1;    DIMM_D6:   3.1.1;       DIMM_D7:   3.2.1;       DIMM_D8:   3.3.1;
97e186
+    DIMM_D9:  3.0.2;    DIMM_D10:  3.1.2;       DIMM_D11:  3.2.2;       DIMM_D12:  3.3.2;
97e186
-- 
97e186
1.9.3