This guide is for admins to troubleshoot seamicro chassis when needed

node operations

ssh into admin@<chassis>

See summary/status

show server summary n/0

Power Off

enable; power-off server n/0 [force]

Power on

enable; power-on server n/0 [force]

reset a node

enable; reset server n/0

Chassis operation

ssh into admin@<chassis>

Power off all nodes

enable; power-off server all [force]

Power on all nodes

enable; power-on server all [force]

Reset chassis

enable; power-off server all [force]
reload

Access serial console of a seamicro node

ssh into admin@<chassis>
enable; server console connect n/0

Note: seamicro nodes start from 0 whereas they are marked from 1 in duffy db. So, say to poweroff n6.pufty, we would do enable; power-off server 5/0